No. | Parameters | Homogeneous Reactor | ||
1 | Full volume(L) | / | ||
2 | Work volume(L) | 0.1 | ||
3 | Design pressure(MPa) | ATM | ||
4 | Work pressure(MPa) | ATM | ||
5 | Design temperature(℃) | 300 | ||
6 | Work temperature(℃) | 250 | ||
7 | Material | Carbon steel |
![]() |
Components for rotary: The chamber material is stainless steel, and other parts are mainly made from carbon steel and spray painted. The vessels for rotating with the volume of 100ml. Strirring speed is only 80 RPM. So, although it could operate 12pcs of vessel a time, the power of motor could be 0.35KW only. Motor and reducer: The motor and reducer are choosen as per required spindle speed and the length of the loop handle.
|
Parts in chamber: The right photo is the inside view of the chamber. The chamber could be heating with the hot air, and finally increase the temperature upto 250°C. Because the vessels are fixed on the loops , and rotating during the opertions. So, all of them could be evenly heated by the hot air. With the effort of rotation and heating from the machine, the medium inside the pressure vessel could react at required conditions. All of the parts inside the chamber are made from stainless steel and mirror polished, so they could resistant the mild corrosion of water vapor contained inside the hot air. The diameter of the rotary axis is designed to withstand the torque caused by the loops. The loops are fixed on the axis with C type part with the screw. |
![]() |
Name | 12 Vessel Rotary Reactor (100 ml) up to 250°C and 3-10Mpa | ||
Model Number | WHGCM-VRR 100-12 | ||
Application | Heating and Rotating the Hydrothermal Autoclave Reaction Vessel |
Design temperature | 300°C | Rotation Speed | 0~80rpm |
Operating temperature | 250°C | Material | Carbon steel |
Filling capacity | 12 pcs | Motor power | 0.35KW |
Vessel Volume | 100ml | Heating power | 1.5KW |
Dimension | 1000 x900 x1000 mm | Weight | 150KGs |
![]() |
![]() |
![]() |
![]() |
![]() |
100ml Vessel Rotary Reactor, High pressure, High Temperature
▲This equipment has an over-temperature power failure and alarm indication system.
When the control temperature exceeds the set upper limit, the instrument will turn off the power and output buzzer alarm automatically, so to ensure the safety of the experiment and personnel.
▲Adopt high temperature resistant silicone sealing strip, with locking type loosening and tightening adjusting door lock.
▲Its door is equipped with double-layer tempered glass.
▲The box housing is treated by an electrostatic spraying process.
▲With frequency converter.
▲Comply with 100ml pressure vessel. The OD of the pressure vessel is 63 to 65mm.
|