00467
No. | Parameters | Tank | ||
1 | Full volume(L) | 139 | ||
2 | Work volume(L) | 120 | ||
3 | Design pressure(MPa) | -0.1~12 | ||
4 | Work pressure(MPa) | -0.1~8 | ||
5 | Design temperature(℃) | 550 | ||
6 | Work temperature(℃) | 500 | ||
7 | Material | S31008 | ||
8 | Stirring speed | / | ||
9 | Motor power (W) | / |
Tank cover nozzle ports -Positive/negative pressure gauge & rupture disc port -Hydrogen gas inlet
-Tank inner temp measuring ports
-Vacuumize port
Note: All nozzle ports can be customized
|
Tank body -Tank inner and tank cover material are stainless steel S31008.
-Equipped with explosion-proof electric lifting device
-Far infrared heating
|
Pilot Reactor Technical Parameters | |||||
Working Volume (L) | 50 | 100 | 200 | 300 | 500 |
Structure Type |
Open Style
Connect Kettle Lid and Kettle Body by Bolts and Nuts on Flange
|
||||
Working pressure | Negative pressure -0.1~20.0 (MPa) | ||||
Working temperature | -196-500°C | ||||
Motor power (W) | 1.1 | 1.5 | 2.2 | 3 | 4 |
Heating power (KW) | 9 | 15 | 18 | 18 | 36 |
Heating type | Direct Electric Heating Fumace, Electric Heater with Thermal Oil Bath, Jacket Circulation with Thermal oil/steam/melt salt | ||||
Discharging type | Discharging from bottom, sampling from kettle lid. | ||||
Mixing Shaft | Self-lubricating wear-resistant sleeve made of stainless steel, suitable for mixing various medium under high speed. | ||||
Stirring type | Impeller, Paddle, Anchor, Turbine, Self-suction, Frame, Screw, Belt, or as per customer's request. | ||||
Seal type | Magnetic Seal, Mechanical Seal, Packing Seal. | ||||
Motor | Ordinary AC motor, or Explosion-Proof motor as per customer request. | ||||
Reactor material | Contacting material inside kettle mainly use SUS304, SUS316L,SUS321, SUS310, as well as titanium, nickel. zirconium, hastelloy.etc, or lined with PTFE, PPL, PFA, Ni (Ni6) according to various reaction medium. | ||||
Kettle lid open port | Gas port, Liquid port, Thermowell port, Solid feeding port, Pressure gauge, Burst disc(safety valve) port, Cooling water inlet/outlet port(or Visual Glass Port and other port according to working pressure). | ||||
Controller Device |
Equipped with auto PlD or PLC controller,Display & control Mixing Speed and Heating Temperature, self-adjustment function,temperature control accuracy +1°C;
Control other instruments, like flow meter, level meter, valves according to reaction
process.
|